AIR PREPARATION


FILTERS

  • UZF SERIES

    Compressed air filters, 16 bar max pressure, G 1/4″ port size; 20 µm standard filtration degree, 5 µm and 40 µm on demand, manual or semiautomatic condensate drainage, transparent techno-polymer bowl, with metallic protection or totally metallic bowl on demand; modular, in line and wall-mounting, conform to ATEX 2GD directive on demand.

    Data sheet
  • EZF SERIES

    Compressed air filters, 16 bar max pressure, G 3/8″, G 1/2″ and G 1″ port sizes; 20 µm standard filtration degree, 5 µm and 40 µm on demand for G 3/8″ and G 1/2″, 40 µm for G 1″; manual or semiautomatic condensate drainage for G 3/8″; manual, semiautomatic or automatic condensate drainagefor G 1/2″ and G 1″; transparent techno-polymer bowl, with glass stiffened polyamide for G 3/8″, transparent techno-polymer with metallic protection standard for G 1/2″ and G 1″, modular, in-line and wall-mounting, conform to ATEX 2GD directive on demand.

    Data sheet

REDUCERS

  • UZRR SERIES

    Compressed air reducer, 16 bar max pressure, G 1/4″ port size, G 1/8″ pressure gauge port size; adjusting ranges: from 0.2 to 2 bar, from 0.4 to 4 bar, from 0.8 to 9 bar and from 1.5 to 12 bar; modular, in-line, wall and panel mount, conform to ATEX 2GD directive on demand.

    Data sheet
  • EZRR SERIES

    Compressed air reducer, 16 bar max pressure, G 3/8″, G 1/2″ and G 1″ port sizes; G 1/8″ pressur gauge port size; adjusting ranges: from 0.2 to 2 bar, from 0.4 to 4 bar, from 0.8 to 8 bar; modular, in-line, wall and panel mount, conform to ATEX 2GD directive on demand.

    Data sheet

PRECISION REDUCERS

  • RRP SERIES

    Compressed air precision pressure reducer with costant leak (max 10 L/m), 10 bar max pressure, G 1/4″ port size, G 1/8″ gauge port size; adjusting ranges: from 0.02 to 0.8 bar, from 0.1 to 4 bar and from 0.5 to 8 bar; repeatability <0,3% full-scale, sensibility <0,7% full scale; in-line, wall and pannel-mounting.

    Data sheet

FILTERS REDUCERS

  • UZRRM /F SERIES

    Compressed air filter reducer, 16 bar max pressure, G 1/4″ port size, G 1/8″ gauge port size; 20 µm filtration degree, 5 µm and 40 µm on demand; manual or semiautomatic condensate drain; pressure adjustment: from 0.2 to 2 bar, from 0.4 to 4 bar, from 0.8 to 9 bar and from 1.5 to 12 bar; modular, in-line and wall-mounting; transparent technopolymer bowl, with metallic protection or total metallic body (no level visualization) on demand; conform to ATEX 2GD directive on demand.

    Data sheet
  • EZRR /F SERIES

    Compressed air filter reducer, 16 bar max pressure, G 3/8″, G 1/2″ and G 1″ port sizes; G 1/8″ gauge port size; 20 µm filtration degree, 5 µm and 40 µm for G 3/8″ and G 1/2″, 40 µm per G 1″ on demand; manual or semiautomatic condensate drain; pressure adjustment: from 0.2 to 2 bar, from 0.4 to 4 bar, from 0.8 to 9 bar and from 1.5 to 12 bar; modular, in-line and wall-mounting; manual or semiautomatic condensate drainage on G 3/8″; manual, semiautomatic or automatic condensate drainage on G 1/2″ and G 1″; transparent technopolymer bowl, glass stiffened polyamide protection on demand on G 3/8″, transparent technopolymer with metallic protection as standard on G 1/2″ and G 1″; conform to ATEX 2GD directive on demand.

    Data sheet

LUBRICATORS

  • UZL SERIES

    Compressed air lubricator, 16 bar max pressure, G 1/4″ port size, modular, in-line and wall-mounting; transparent technopolymer bowl, with metallic protection or total metallic body (no level visualization) on demand; conform to ATEX 2GD directive on demand.

    Data sheet
  • EZL SERIES

    Compressed air lubricator, 16 bar max pressure, G 3/8″, G 1/2″ and G 1″ port size; modular, in-line and wall-mounting; transparent technopolymer bowl, glass stiffened polyamide protection on demand on G 3/8″, transparent technopolymer with metallic protection as standard on G 1/2″ and G 1″; conform to ATEX 2GD directive on demand.

    Data sheet

FILTERS REDUCERS + LUBRICATOR

  • UZRRM SERIES

    Compressed air filter reducer + lubricator, 16 bar max pressure, G 1/4″ port size, G 1/8″ gauge port size; pressure adjustment: from 0.2 to 2 bar, from 0.4 to 4 bar, from 0.8 to 9 bar or from 1.5 to 12 bar; oil mist or micro-oil mist lubrication; transparent technopolymer bowl, with metallic protection or total metallic body (no level visualization) on demand; conform to ATEX 2GD directive on demand.

    Data sheet
  • EZRR SERIES

    Compressed air filter reducer + lubricator, 16 bar max pressure, G 3/8″, G 1/2″ and G 1″ port sizes; G 1/8″ gauge port size; pressure adjustment: from 0.2 to 2 bar, from 0.4 to 4 bar or from 0.8 to 8 bar; oil mist, oil mist, N.O. electric contact or oil mist, N.C. electric contact; transparent technopolymer bowl, glass stiffened polyamide protection on demand on G 3/8″, transparent technopolymer with metallic protection as standard on G 1/2″ and G 1″; manual, semiautomatic or automatic condensate drainage; conform to ATEX 2GD directive on demand.

    Data sheet

FILTERS + REDUCERS + LUBRICATORS

  • UZF SERIES

    Compressed air filter + reducer + lubricator, 16 bar max pressure, G 1/4″ port size, G 1/8″ gauge port size; pressure adjustment: from 0.2 to 2 bar, from 0.4 to 4 bar, from 0.8 to 9 bar or from 1.5 to 12 bar; oil mist or micro-oil mist; transparent technopolymer bowl, with metallic protection or total metallic body (no level visualization) on demand; manual or semiautomatic condensate drainage; conform to ATEX 2GD directive on demand.

    Data sheet
  • EZF SERIES

    Compressed air filter + reducer + lubricator, 16 bar max pressure, G 3/8″, G 1/2″ and G 1″ port sizes; G 1/8″ gauge port size; pressure adjustment: from 0.2 to 2 bar, from 0.4 to 4 bar or from 0.8 to 8 bar; oil mist, oil mist N.O. electric contact or oil mist N.C. electric contact; transparent technopolymer bowl, glass stiffened polyamide protection on demand on G 3/8″, transparent technopolymer with metallic protection as standard on G 1/2″ and G 1″; manual, semiautomatic or automatic condensate drainage; conform to ATEX 2GD directive on demand.

    Data sheet

SOFT STARTER

  • UZAP SERIES

    Soft start valve, pneumatic or solenoid pilot; UZAP/A4 fully automatic without pilot version; 10 bar max pressure, G 1/4″ port size, G 1/8″ pilot port size; modular, in-line or wall-mounting; conform to ATEX 2GD directive on demand.

    Data sheet
  • EZAP SERIES

    Soft start valve, pneumatic or solenoid pilot; 10 bar max pressure, G 3/8″, G 1/2″ or G 1″ port sizes; G 1/8″ pilot port size; modular, in-line or wall-mounting; conform to ATEX 2GD directive on demand.

    Data sheet

SHUT-OFF VALVES

  • UZVL SERIES

    Compressed air shut-off valve, lockable in exhaust position, 16 bar max pressure, G 1/4″ port size, modular and in-line mounting, conform to ATEX 2GD directive on demand.

    Data sheet
  • EZVL SERIES

    Compressed air shut-off valve, lockable in exhaust position, 16 bar max pressure, G 3/8″, G 1/2″ and G 1″ port sizes; modular and in-line mounting, conform to ATEX 2GD directive on demand.

    Data sheet

PROPORTIONAL VALVES

  • EPR SERIES

    Compressed air proportional pressure valve, 10 bar max pressure, G 3/8″, G 1/2″ and G 1″ port sizes; G 1/8″ gauge port size; pressure adjusting: from 0 to 1 bar, from 0 to 5 bar or from 0 to 9 bar; control signal: voltage from 0 to 5 VDC or from 0 to 10 VDC user selectable; current: from 0 to 20 mA DC or from 4 to 10 mA DC user selectable, four control ON/OFF signal; feedback signal: from 1 to 5 VDC, from 4 to 20 mA DC, 24 VDC PNP, 24 VDC NPN.

    Data sheet

PRESSURE GAUGES

  • MA SERIES

    Compressed air pressure gauge, pressure ranges: from 0 to 1 bar, from 0 to 4 bar, from 0 to 6 bar and from 0 to 12 bar; 40, 50, 63 and 100 mm gauge diameter; G 1/8″ and G 1/4″ connection sizes; direct axial, direct radial, pannel with flange or panel with braket mounting.

    Data sheet

PRESSURE SWITCHES

  • PR SERIES

    Air or non-corrosive or incomusible gases digital/analog pressure switch; from -1 to 10 bar operating pressure, from 0 to 10 bar recommended pressure; switch voltage: from 12 to 24 VDC ± 10%; PNP or NPN on demand switch output; analog output: from 1 to 5 V < ± 2,5%; kPa, MPa, bar, psi measurement units; manually adjustable hysteresis from 1 to 10% of rated pressure or automatically arranged at 3% of full-scale.

    Data sheet
  • Delta logo
  • Eaton logo
  • Lucifer logo
  • MP Filtri logo
  • Norgren logo
  • Olaer logo
  • Parker logo
  • RRR logo
  • Schubert&Salzer logo
  • Star logo
  • Waircom logo
  • Watts logo